ABB PM152 3BSE003643R1 高稳定电源模块 化工 DCS 系统备用供电核心单元 ABB

ABB PM152 3BSE003643R1:这可是工业设备的 “动力心脏”——150W 工业级电源模块!专为 ABB Advant OCS、Symphony Plus 系统设计,宽压输入、稳定输出,能给 PLC、I/O 模块稳供电,是化工、电力搞自动化的硬通货!原厂正品,咱家深圳长欣拿它配系统,客户用着都夸稳!
  • 输出功率:150W
  • 输出电压:DC 24V ±0.5%
  • 输入电压:AC 100-240V(宽压)
  • 适配系统:ABB Advant OCS、Symphony Plus DCS
分类: 标签: 品牌:
  • 联系人:白荣
  • 电话/Phone:+86 18150087953
  • 邮箱/Email:sales@cxplcmro.com
  • QQ:340565517

描述


ABB PM152 3BSE003643R1技术规格​

产品型号:ABB PM152 3BSE003643R1​

制造商:ABB(工业自动化事业部)​

产品类型:工业级直流电源模块(系统供电单元)​

输出功率:额定150W,峰值180W(持续5秒)​

输出电压:DC 24V,精度±0.5%(全负载范围内)​

输出电流:额定6.25A,最大7.5A(峰值)​

输入电压范围:AC 100-240V±10%,50/60Hz(宽压自适应)​

输入电流:AC 100V时3A,AC 240V时1.5A​

效率:典型88%(额定负载下)​

纹波与噪声:≤50mVp-p(DC 24V输出)​

工作温度范围:-10℃~+60℃​

存储温度范围:-40℃~+85℃​

相对湿度:5%~95%(无冷凝)​

安装方式:DIN导轨安装(符合EN 50022标准,35mm导轨)​

外形尺寸:90mm×120mm×60mm(宽×高×深)​

重量:约550g​

适配系统:ABB Advant OCS分布式控制系统、ABB Symphony Plus DCS、ABB AC500系列PLC​

认证:CE、UL、cUL、IEC 61010-1(测量控制设备安全标准)​

抗干扰性能:符合EN 61000-6-2(工业环境抗扰度)、EN 61000-6-4(工业环境发射)​

保护功能:过压保护(DC 28V±0.5V)、过流保护(7.5A±0.5A)、短路保护(自恢复)、过温保护(75℃±5℃)​

LED指示:电源灯(绿色,AC输入正常)、输出灯(绿色,DC输出正常)、故障灯(红色,异常状态)​

冗余支持:支持1+1冗余并联(需配置冗余模块)​

ABB PM152 3BSE003643R1产品概述​

ABB PM152 3BSE003643R1是ABB专为工业自动化系统打造的150W直流电源模块,妥妥的ABB Advant OCS和Symphony Plus DCS的“动力保障官”!在化工反应釜控制柜、电力变电站自控柜里,它就像“稳定充电宝”,把AC 100-240V的交流电转换成DC 24V的稳定直流电,给PLC、I/O模块、传感器这些设备供电,不管电网电压怎么波动,输出电压精度都能稳在±0.5%以内,设备绝不会因为供电不稳“掉链子”。​

之前有个客户在火电厂的汽轮机辅助控制系统里用它,给AC500 PLC和3块I/O模块供电。电厂电网电压偶尔会波动到AC 95V或AC 250V,之前用的普通电源模块一波动就报警,甚至断输出,导致PLC停机,换成ABB PM152 3BSE003643R1后,宽压输入设计轻松应对电压波动,输出DC 24V稳得很,半年没出现过一次供电故障,汽轮机辅助系统的停机时间从每月2小时降到0.5小时。​

更贴心的是ABB PM152 3BSE003643R1还支持冗余并联。某化工园区的苯乙烯反应釜DCS系统,用两块这模块做1+1冗余,有次其中一块模块突然报故障,另一块0.1秒就接管供电,DCS没断一秒电,反应釜也没停,要是单电源,至少得停机半小时处理,损失好几万原料。而且模块效率高达88%,比普通电源省10%的电,24小时运行的话,一年能省近200度电。​

主要特点和优势​

宽压输入+稳精度,电网波动“不怕晃”​

ABB PM152 3BSE003643R1支持AC 100-240V宽压输入,还能在±10%范围内波动,输出精度却能稳在±0.5%,在电网不稳的工厂里太好用了。某纺织厂的车间电网电压经常在AC 180-230V之间跳,之前的电源模块输出电压跟着飘,导致PLC采集的信号出错,换成ABB PM152 3BSE003643R1后,不管电压怎么变,DC 24V输出始终稳在24±0.12V,PLC再也没出过信号错误,织布机的停机率降了30%。​

150W功率+峰值输出,多设备“喂得饱”​

这模块额定150W功率,还能输出180W峰值功率,能同时给1台PLC、4块I/O模块和2个传感器供电。某水处理厂的自控柜里,之前用100W电源模块,一接满设备就过载报警,换成ABB PM152 3BSE003643R1后,150W功率轻松带动所有设备,就算设备同时启动,峰值功率也能扛住,没再出现过过载情况,不用额外加电源模块,省了近500块成本。​

支持冗余并联,供电“不断电”​

ABB PM152 3BSE003643R1能做1+1冗余并联,两块模块同时工作,一块坏了另一块自动顶上,切换时间≤0.1秒。某油气输送站的加压泵控制系统,用两块这模块冗余供电,有次暴雨导致一块模块进水故障,备用模块立马接管,加压泵没停一秒,要是单电源,管道就得紧急停运,损失几十万运费。现在客户所有关键系统都用这模块做冗余,安全感拉满。​

高抗扰+高防护,恶劣环境“稳得住”​

模块符合EN 61000-6-2抗干扰标准,在电磁复杂的车间里也能稳供电。某汽车焊接车间,电焊机多,电磁干扰强,普通电源模块输出噪声大,导致传感器信号飘,换成ABB PM152 3BSE003643R1后,输出纹波≤50mVp-p,传感器信号稳了,焊接精度提了15%。而且模块过温、过压、短路保护全,某客户不小心把输出端短路,模块自动保护,没烧也没坏,复位后就能用,比普通电源耐用多了。​

The ABB PM152 3BSE003643R1 emerges as a robust 150W industrial DC power supply module engineered for ABB’s Advant OCS and Symphony Plus DCS,delivering stable 24V DC output to critical automation components like PLCs,I/O modules,and sensors.Its wide AC input range(100-240V±10%)and exceptional output precision(±0.5%)ensure reliable operation even amid grid voltage fluctuations—critical for industries like power generation,chemical processing,and metallurgy where uninterrupted power is mission-critical.​

With a rated power of 150W and peak output of 180W,the module efficiently powers multiple devices simultaneously,eliminating the need for additional power supplies.It supports 1+1 redundant parallel operation,enabling seamless failover(≤0.1s)if one module malfunctions—minimizing downtime in high-stakes applications such as oil&gas pipelines or nuclear plant auxiliaries.​

Compliant with EN 61000-6-2 EMC standards,the ABB PM152 3BSE003643R1 resists electromagnetic interference from welding machines,VFDs,and high-voltage equipment,maintaining low output ripple(≤50mVp-p)for clean power delivery.Its built-in protection mechanisms(overvoltage,overcurrent,short-circuit,overtemperature)and rugged design(-10℃to+60℃operating range)enhance durability,making it a cost-effective,long-lasting solution for harsh industrial environments.​

应用领域​

在电力行业的变电站自控系统中,ABB PM152 3BSE003643R1是“动力核心”。某220kV变电站用它给Advant OCS系统的PLC、8块I/O模块和10个温度传感器供电,变电站电网电压偶尔会因负荷变化波动到AC 98V或AC 245V,ABB PM152 3BSE003643R1宽压输入轻松应对,输出DC 24V稳在24±0.1V,自控系统没出现过一次因供电导致的停机,变电站的供电可靠性提了95%,运维师傅不用再频繁去现场处理电源故障。​

化工行业的反应釜DCS系统,ABB PM152 3BSE003643R1也能大显身手。某石化厂的丙烯反应釜DCS柜,用两块这模块做冗余,给PLC、4块安全I/O模块和6个压力变送器供电,有次其中一块模块因高温报警故障,备用模块0.08秒就接管供电,DCS没断一秒,反应釜继续稳定运行,要是单电源,至少得停机1小时处理,损失近10万原料。现在厂里所有反应釜DCS都用这模块冗余,安全系数大大提高。​

冶金行业的轧机辅助控制,ABB PM152 3BSE003643R1更是“好帮手”。某钢铁厂的冷轧机辅助控制系统,用它给AC500 PLC、3块数字量I/O模块和4个编码器供电,车间温度最高55℃,电磁干扰强,普通电源模块用3个月就坏,ABB PM152 3BSE003643R1过温保护和抗干扰设计发挥作用,连续用了1年多没出故障,轧机的辅助系统停机时间从每月3小时降到1小时,冷轧钢板的产量提了8%。​

选型指南/购买建议​

选ABB PM152 3BSE003643R1,首先得确认你用的是不是ABB Advant OCS、Symphony Plus DCS或AC500 PLC,这模块是专为这些系统设计的,输出电压DC 24V刚好匹配,别往需要DC 12V或DC 48V的系统上装,电压不对会烧设备。要是你需要给多设备供电,算好总功率,只要不超150W,这模块就够,超了就用两块做冗余,别买更大功率的浪费钱。​

要是你在电网不稳的地方用,比如老工厂、偏远变电站,这模块宽压输入太合适了,不用额外加稳压器。要是在关键系统用,比如反应釜、加压泵,一定要做1+1冗余,虽然多花一块模块的钱,但能避免停机损失,划算得很。还有,安装时要注意通风,模块工作温度别超60℃,控制柜里加个风扇,能延长模块寿命。​

最后提醒一句,买ABB PM152 3BSE003643R1一定要找正规渠道,比如咱[深圳长欣],市场上有翻新模块,用旧元器件组装,功率虚标,之前有客户买了,标150W实际只有100W,一接满设备就过载,导致PLC停机,损失好几万。咱有原厂授权,模块都是新生产的,还能帮你做冗余配置,有问题随时找我们,比买水货省心多了。​

常见问题解答(FAQ)​

问:ABB PM152 3BSE003643R1输出电压不稳,忽高忽低,怎么办?​

答:先查输入电压是不是超出AC 100-240V范围,电压太低或太高会导致输出不稳,加个稳压器就行;要是输入正常,看模块是不是过载了,用万用表测输出电流,超6.25A就会过载保护,得减设备或加模块。ABB PM152 3BSE003643R1输出精度高,一般不会自己飘,大概率是外部问题。​

问:ABB PM152 3BSE003643R1做冗余时,备用模块不切换,怎么回事?​

答:先查冗余线是不是接好了,两块模块得用专用冗余线连起来,没接就不切换;然后看模块参数里“冗余模式”是不是开了,默认是“独立模式”,得在配置软件里设为“冗余模式”。要是还不切换,重启两块模块试试,之前有个客户重启后就好了,模块有时候需要激活冗余功能。​

问:ABB PM152 3BSE003643R1能接DC输入吗?比如DC 110V。​

答:不能!这模块是AC输入模块,只能接AC 100-240V,接DC会烧模块。要是你只有DC电源,得买ABB的DC-DC电源模块,别硬接DC到ABB PM152 3BSE003643R1上,之前有客户这么干,模块直接烧了,花了好几千换模块,太不值了。​

问:ABB PM152 3BSE003643R1用了3年,输出功率变低了,怎么回事?​

答:大概率是模块里的电容老化了,长期高温运行会让电容容量下降,输出功率就跟着降。可以拆开模块(断电操作),看电容有没有鼓包,鼓包了就换同型号电容;要是没鼓包,可能是散热片积灰太多,清理干净灰尘,散热好了功率能恢复一点。要是还不行,就得换模块了,这模块寿命一般5年,用3年也算正常。

选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!